<< 点击显示目录 >> 主页 振动监测 > X20(c)CM4810使用手册 > 寄存器说明 - Register description > 模拟量输入功能 - Analog input functions > 模拟量输入尺度 - AnalogInputScale |
Name:
AnalogInputScale01
名称:
AnalogInputScale01
This register can be used to specify the scale of the 4 analog inputs (AnalogInput). If the actual value is greater than the value configured in this register, the respective register for the analog input (AnalogInput) is limited to the positive maximum (32767).
For example, if ±128 is configured for AnalogInput04, then the 16 bits represent a value range of ±128 g or without units if the crest factor has been calculated.
这个寄存器可以用来指定 4 个模拟量输入 (AnalogInput)的尺度。 如果实际值大于该寄存器中配置的值,则相应的模拟量输入 (AnalogInput) 寄存器的值被限制为正最大值(32767)。
例如,如果为 AnalogInput04 配置了 ±128,则用 16 位数据代表 ±128g 的值的范围,如果已经计算出(crest factor,裕度),则没有单位。
Information: 说明: The configured scaling value is always based on a 100 mV/g sensor. Any sensor that has a different sensor sensitivity must be reflected in the configuration. 配置的尺度值始终基于 100 mV/g 的传感器,任何具有不同灵敏度的传感器都必须反映在配置中。 |
Data type 数据类型 |
Values 值 |
Bus controller default setting 总线控制器默认值 |
UINT |
See bit structure. 请参阅位结构。 |
0x8888 0x8888 |
Bit structure:
位结构:
位 |
Description 描述 |
Value 值 |
Information 说明 |
0 - 3 |
Scaling for AnalogInput01 AnalogInput01 的尺度 |
0 |
Invalid 无效 |
1 |
±1 |
||
2 |
±2 |
||
3 |
±4 |
||
4 |
±8 |
||
5 |
±16 |
||
6 |
±32 |
||
7 |
±64 |
||
8 |
±128 (bus controller default setting) ±128 (总线控制器默认值) |
||
9 to 15 |
Invalid 无效 |
||
4 - 7 |
Scaling for AnalogInput02 AnalogInput02 的尺度 |
x |
For possible values, see AnalogInput01. 见 AnalogInput01. |
8 - 11 |
Scaling for AnalogInput03 AnalogInput03 的尺度 |
x |
For possible values, see AnalogInput01. 见 AnalogInput01. |
12 - 15 |
Scaling for AnalogInput04 AnalogInput04 的尺度 |
x |