<< 点击显示目录 >> 主页 振动监测 > X20CM4800X > Register description > Communication > Status of the module |
X20CM4800X - Data sheet V1.04
MeasurementState01 to MeasurementState04
BufferOverflow01 to BufferOverflow04
BrokenWire01 to BrokenWire04
This register specifies the module status.
Bit structure:
Description |
Value |
Information |
|
0 |
MeasurementState01 |
0 |
Measurement of channel 1 stopped |
1 |
Measurement of channel 1 running |
||
... |
|
... |
|
3 |
MeasurementState04 |
0 |
Measurement of channel 4 stopped |
1 |
Measurement of channel 4 running |
||
4 |
0 |
No buffer overflow on channel 1 |
|
1 |
Buffer overflow on channel 1 |
||
... |
|
... |
|
7 |
0 |
No buffer overflow on channel 4 |
|
1 |
Buffer overflow on channel 4 |
||
8 |
BrokenWire01 |
0 |
No error on channel 1 |
1 |
Open circuit - Channel 1 |
||
... |
|
... |
|
11 |
BrokenWire04 |
0 |
No error on channel 4 |
1 |
Open circuit - Channel 4 |
||
12 - 15 |
Reserved |
- |
|
Each channel is equipped with an internal buffer of 50 kB. Depending on the set sampling rate, data resolution and MTU size, a buffer overflow occurs at the earliest after approx. 250 ms if the data is not transferred via Flatstream. The overflow must be acknowledged by the application using register BufferOverflowAck0x.