原始频率最大值 - MaxFrequencyRaw

<< 点击显示目录 >>

主页  振动监测 > X20(c)CM4810使用手册 > 寄存器说明 - Register description  > 频带配置寄存器 - Frequency band configuration registers >

原始频率最大值 - MaxFrequencyRaw

 

Name:

MaxFrequencyRaw01

名称:

MaxFrequencyRaw01

 

Registers for setting the maximum frequency of the channel. Reducing the maximum frequency allows the frequency resolution in the spectrum to be increased.

用于设置通道最大频率的寄存器。降低最大频率可以提高频率分辨率。

Data type

数据类型

Values

Bus controller default setting

总线控制器的默认设置

UINT

See bit structure.

请参阅位结构。

8738

 

Bit structure:

位结构:

Bit

Description

描述

Value

Information

说明

0 - 3

Maximum frequency for channel 1

通道 1 的最大频率

0

10000 Hz

1

5000 Hz

2

2000 Hz (bus controller default setting)

2000 Hz (总线控制器的默认设置)

3

1000 Hz

4

500 Hz

5

200 Hz

6 to 15

Invalid

4 - 7

Maximum frequency for channel 2

通道 2 的最大频率

x

For possible values, see channel 1.

见通道 1.

8 - 11

Maximum frequency for channel 3

通道 3 的最大频率

x

For possible values, see channel 1.

见通道 1.

12 - 15

Maximum frequency for channel 4

通道 4 的最大频率

x

For possible values, see channel 1.

见通道 1.

 

Overview of the maximum frequency of the raw signal

原始信号的最大频率概述

Maximum frequency

最大频率

Sampling frequency

采样频率

Duration of measurement

测量持续时间

Frequency resolution in the frequency spectrum

频率分辨率

10000 Hz

25781 Hz

0.3178 s

3.1471 Hz

5000 Hz

12891 Hz

0.6355 s

1.5736 Hz

2000 Hz

5156 Hz

1.5888 s

0.6294 Hz

1000 Hz

2578 Hz

3.1775 s

0.3147 Hz

500 Hz

1289 Hz

6.3550 s

0.1574 Hz

200 Hz

516 Hz

15.8875 s

0.0629 Hz

Important information for configuring the maximum frequency

The frequency range must be larger than the damage frequency but should otherwise be kept as small as possible in order to achieve a good resolution.

When using broadband values (e.g. PeakRaw), only the largest peak value is returned during a measurement. Using a longer measurement time at a lower frequency can lead to the measured value being overlooked in some applications.

The maximum frequency influences the size of the sampling rate and can be configured using register AnalogInput.

 

配置最大频率的重要信息

频率范围必须大于损坏频率,但应保持尽可能小的频率范围,以获得良好的分辨率。

当使用宽频的值(例如PeakRaw)时,在测量过程中只返回最大的峰值。在某些应用中,在较低频率下使用较长的测量时间可能会导致测量值被忽略。

最大频率(maximum frequency)会影响采样速率的大小,可以使用 AnalogInput 寄存器进行配置。